Avoiding Cracks in Stack Bond Abbotsford BC

I have heard that masonry laid in stack bond is more likely to crack than masonry laid in running bond. Why? Assuming walls were built using the same mortar and brick in Abbotsford, why wouldn't the vertical joints in stack bond be as strong as the horizontal joints in both stack bond and running bond?

Keystone Architecture & Planning Ltd
(604) 850-0577
110 2881 Garden Street
Abbotsford, BC
 
Craven Huston Powers Architects
(604) 793-9445
9355 Young Road
Chilliwack, BC
 
H S Design
(250) 338-6822
811-3030 Kilpatrick Avenue
Courtenay, BC
 
Trace Wisse Designworks
(604) 792-0826
3-45953 Airport Road
Chilliwack, BC
 
Robert Boyle Architecture Inc
(250) 753-3495
360 Wesley Street
Nanaimo, BC
 
4th Dimension Design & Drafting Services
(604) 557-9465
1 2686 Langdon Street
Abbotsford, BC
 
Portico Design Group Ltd
(604) 275-5470
1141-11871 Horseshoe Way
Richmond, BC
 
Pattison Eric
(604) 525-3232
202-204 Sixth Street
New Westminster, BC
 
Accurate Designers & Builders
(604) 277-5079
8520 Ryan Road
Richmond, BC
 
Leslie & Renney Construction Ltd
(604) 937-0108
371 Walker Street
Coquitlam, BC
 

Avoiding Cracks in Stack Bond

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: August 1, 1994

I have heard that masonry laid in stack bond is more likely to crack than masonry laid in running bond. Why? Assuming walls were built using the same mortar and brick, why wouldn't the vertical joints in stack bond be as strong as the horizontal joints in both stack bond and running bond?

Unreinforced stack bond walls are more likely to crack vertically than walls built with running bond. That is why ACI 530 requires any masonry laid in other than running bond to have horizontal joint reinforcement spaced no further than 4 feet apart in order to control cracking.In a running bond wall, any vertical crack must either pass through a brick at every other course or follow the mortar through head and bed joints. Usually the weakest path is through the units. Therefore the wall's strength is determined mainly by the strength of the units, not the mortar bond strength at head joints. In stack bond walls that are not reinforced, resistance to vertical cracking depends solely on mortar-to-brick bond, which is weaker in vertical joints than in horizontal joints. Better bond is developed in horizontal joints because the weight of the masonry keeps the joints under pressure throughout construction. If cracks do develop, they generally are very small because of this compression.

Click here to read full article from Masonry Construction