Integrating Parapet and Roofing Flashing Abbotsford BC

On the inside face of a parapet or wherever a masonry wall intersects a lower roof, I have seen cases where the masonry flashing in Abbotsford exits the wall one or more courses above the top of the retaining bar for the roof base flashing.

Crown Roofing & Drainage
1071 Millcarch Street
Richmond, BC
Services
Specialty Contractor
Membership Organizations
Better Business Bureau, Certified Contractors Network (CCN), GAF ELK Master Elite

Data Provided by:
Pley Roofing
723-9170
4440 Bute Street
Port Alberni, BC
 
Peak Roofing Inc.
(604) 727-5405
126-7341, 19 avenue
Burnaby, BC
 
Maxim Building Solutions
(778) 384-4296
159 Baltic St
Coquitlam, BC
 
Also Roofing Corp.
(778) 834-8342
729 Clarke Road
Coquitlam, BC
 
Affiliated Roofers
(604) 937-7730
112A-81 Golden Drive
Coquitlam, BC
 
Design Roofing & Sheet Metal
(604) 944-2977
1385 Kingsway Ave
Port Coquitlam, BC
 
BestWest Roofing Inc.
604-779-5317
New Westminster, BC

Data Provided by:
Chisholm Roofing Ltd.
(604) 325-8099
1083 East Kent Avenue North
Vancouver, BC
 
Extreme Weather Roofing
(778) 991-9414
Lower Mainland - Tri-Cities
Lower Mainnland - Tri-Cities, BC
 
Data Provided by:

Integrating Parapet and Roofing Flashing

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: March 1, 2001

On the inside face of a parapet or wherever a masonry wall intersects a lower roof, I have seen cases where the masonry flashing exits the wall one or more courses above the top of the retaining bar for the roof base flashing. Will this cause any problems?

There can be problems whenever the roof base flashing and the masonry through-wall flashing are not properly integrated. This is especially true if the masonry flashing stops or is held back slightly at the face of the masonry. If the flashing does not extend beyond the face of the wall, there is a chance the water may run around the end of the flashing and re-enter the wall below. Another good reason for projecting the through-wall flashing beyond the face of the wall is to prevent the outlet edge of the masonry flashing from being inadvertently covered when the roof membrane and roof base flashing are replaced. This would seal off the masonry flashing and route the water under the roofing. (DonÆt laugh; IÆve seen it happen.)

But there can be problems even when the masonry flashing does project beyond the face of the wall if it exits more than one or two courses above the roof base flashing. When water flows across the face of the wall or out from the weep holes, it will flow over the masonry between the bottom of the masonry flashing and the top of the roof base flashing.

Click here to read full article from Masonry Construction