Lateral Bracing Walls for Sloped Roofs Edmonton AB

Some designs require that sloped open web joist roof systems be laterally braced to a concrete masonry fire wall in Edmonton. When non-bearing masonry walls need to be braced by steel joists that are sloped, prefabricated metal weld plates should be embedded into the masonry walls.

Always Plumbing
780-489-8118
Edmonton, AB

Data Provided by:
Natural Born Painters Ltd
(780) 914-2621
4 Hunt Road
edmonton, OO
 
Coventry Homes
(780) 453-5100
17615 - 111 Avenue NW
Edmonton, OO
 
Acro Construction
(780) 863-5882
204 6208 180 Street
Edmonton, AB
 
Black Dog Drilling & Environmental Services Ltd.
(403) 396-6389
Box 9137
Sylvan Lake, AB
Services
Water Well Drilling & Services
Awards
Small Employer Certificate of Recognition
Membership Organizations
AWWDA, BBB, CGWA

lombard development inc
(780) 482-1334
11941 126 street
edmonton, AL
 
Nilex Inc.
(780) 463-9535
9304 – 39 Avenue
Edmonton, AB
 
Coventry Homes
(780) 453-5100
17615 - 111 Avenue NW
Edmonton, AB
Services
House Styles, House Plans, Home Builder, Master Builder, New Home Development, New Home Builder

JP Trucking
(780) 966-7308
1121
edmonton`, AB
 
TROL Excavating Ltd
(403) 317-0654
107 Couleecreek Lane S
Lethbridge, AB
 
Data Provided by:

Lateral Bracing Walls for Sloped Roofs

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: April 1, 2007

By Walter A. Laska

Some designs require that sloped open web joist roof systems be laterally braced to a concrete masonry fire wall. When non-bearing masonry walls need to be braced by steel joists that are sloped, prefabricated metal weld plates should be embedded into the masonry walls. The concrete masonry cell directly behind the welding plate should be solidly filled with mortar or grout.

Weld plates, such as those manufactured by Trico Masonry Products, must be installed to align with the steel joists. The metal weld plates should be fabricated and delivered to the jobsite prior to the beginning of construction. The weld plates can be adjusted easily, assuring correct installation.

Lateral bracing of the wall can be achieved by extending the horizontal bridging angles and welding them to the welding plates secured to the wall. The extended angle should be aligned with the horizontal bridging to prevent crimping in the joist chords due to pressure induced by wind loads.

Extending the horizontal bridging and connecting it to the masonry wall permit lateral loads to be transferred into the roof diaphragm, which braces the wall against wind loads. This arrangement eliminates the need for columns, piers, pilasters, or cross walls for lateral bracing if the wall is designed and constructed within height limitations allowed by code.