Lateral Bracing Walls for Sloped Roofs Saint-Jérôme QC

Some designs require that sloped open web joist roof systems be laterally braced to a concrete masonry fire wall in Saint-Jérôme. When non-bearing masonry walls need to be braced by steel joists that are sloped, prefabricated metal weld plates should be embedded into the masonry walls.

Construction Nevala
(450) 692-2641
10, Rue Brosseau
Chateauguay, QC
 
Construction Raoul Pelletier (1997) Inc
(418) 837-2147
3650, boulevard de la Rive-Sud
Levis, QC
 
The Energuy Home Energy Advisor - Gainteau
(877) 636-3748
Gainteau, QC

Data Provided by:
Construction R. Cloutier Inc
(819) 536-5646
4450 Avenue Jean-Duchesne
Shawinigan, QC
 
Groupe Gje Lavoie Inc
(514) 684-5584
4025 boul des Sources
Dollard-Des-Ormeaux, QC
 
Construction Alain Larouche
(819) 797-8749
21 Avenue Gagnon
Rouyn-Noranda, QC
 
Construction R Desgroseilliers
(450) 698-0329
274, Rue Birch
Chateauguay, QC
 
Construction Denis Rousseau Inc
(819) 539-6851
3033 Rue Daemen
Shawinigan, QC
 
Fedelenergie Inc
(514) 592-4557
276 rue Baffin
Dollard-Des-Ormeaux, QC
 
Construction Rene Voyer
(514) 620-7733
284 Rue Renoir
Dollard-Des-Ormeaux, QC
 
Data Provided by:

Lateral Bracing Walls for Sloped Roofs

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: April 1, 2007

By Walter A. Laska

Some designs require that sloped open web joist roof systems be laterally braced to a concrete masonry fire wall. When non-bearing masonry walls need to be braced by steel joists that are sloped, prefabricated metal weld plates should be embedded into the masonry walls. The concrete masonry cell directly behind the welding plate should be solidly filled with mortar or grout.

Weld plates, such as those manufactured by Trico Masonry Products, must be installed to align with the steel joists. The metal weld plates should be fabricated and delivered to the jobsite prior to the beginning of construction. The weld plates can be adjusted easily, assuring correct installation.

Lateral bracing of the wall can be achieved by extending the horizontal bridging angles and welding them to the welding plates secured to the wall. The extended angle should be aligned with the horizontal bridging to prevent crimping in the joist chords due to pressure induced by wind loads.

Extending the horizontal bridging and connecting it to the masonry wall permit lateral loads to be transferred into the roof diaphragm, which braces the wall against wind loads. This arrangement eliminates the need for columns, piers, pilasters, or cross walls for lateral bracing if the wall is designed and constructed within height limitations allowed by code.

Click here to read full article from Masonry Construction