Lateral Bracing Walls for Sloped Roofs Windsor ON

Some designs require that sloped open web joist roof systems be laterally braced to a concrete masonry fire wall in Windsor. When non-bearing masonry walls need to be braced by steel joists that are sloped, prefabricated metal weld plates should be embedded into the masonry walls.

Decks and Fences by Ryan
(519) 946-3042
1361 Ouellette Avenue
Windsor, OO
 
HMP Home Inspections Inc.
(905) 457-8602
11 lauchlin cres.
georgetown, ON
Services
Pre-listing, Pre-purchase, Tarion new home
Membership Organizations
NHI. PHPIC. National Home Inspector
Prices and/or Promotions
Free Home Reference Encyclopedia

The Energuy Home Energy Advisor - Kingston
(877) 636-3748
Kingston, ON

Data Provided by:
Snow's Construction
(416) 432-8458
129 Times Road
Toronto, ON
 
Stone Manor Developments
(905) 760-9353
25 Edilcan Drive
Vaughan, ON
 
The Energuy Home Energy Advisor - Milton
(877) 636-3748
Milton, ON

Data Provided by:
Homepros Basement Waterproofing
(905) 823-4663
1616 Hobbs Crest
Mississauga, ON
 
CanSpec Inspection Services - Thunder Bay
(877) 672-3242
Thunder Bay, ON

Data Provided by:
Lamarche's Drywall Solutions
(613) 371-7209
1785 Riverside Dr
Ottawa, ON
 
SJ Garden Sheds & Decks
(519) 808-7433
8774 LaSalle Line
Watford, ON
 
Data Provided by:

Lateral Bracing Walls for Sloped Roofs

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: April 1, 2007

By Walter A. Laska

Some designs require that sloped open web joist roof systems be laterally braced to a concrete masonry fire wall. When non-bearing masonry walls need to be braced by steel joists that are sloped, prefabricated metal weld plates should be embedded into the masonry walls. The concrete masonry cell directly behind the welding plate should be solidly filled with mortar or grout.

Weld plates, such as those manufactured by Trico Masonry Products, must be installed to align with the steel joists. The metal weld plates should be fabricated and delivered to the jobsite prior to the beginning of construction. The weld plates can be adjusted easily, assuring correct installation.

Lateral bracing of the wall can be achieved by extending the horizontal bridging angles and welding them to the welding plates secured to the wall. The extended angle should be aligned with the horizontal bridging to prevent crimping in the joist chords due to pressure induced by wind loads.

Extending the horizontal bridging and connecting it to the masonry wall permit lateral loads to be transferred into the roof diaphragm, which braces the wall against wind loads. This arrangement eliminates the need for columns, piers, pilasters, or cross walls for lateral bracing if the wall is designed and constructed within height limitations allowed by code.

Click here to read full article from Masonry Construction