Soaping Masonry Winnipeg MB

What are soaps in masonry walls and when are they used? The term "soap" is often used to describe masonry units in Winnipeg cut to reduce their depth. The Brick Industry Association (BIA) defines soaps as "A masonry unit of normal face dimensions having a nominal 2-inch. thickness." In actual construction, I have seen soaps cut down to a depth of 1 inch.

Albany Keystone Builders & Renovators
(204) 989-8033
Winnipeg, MB

Data Provided by:
Warm Home Insulation
(204) 258-2505
85 Egerton Rd.
Winnipeg, MB
 
Nisby Home Renovations Ltd.
(204) 888-2288
Winnipeg, MB

Data Provided by:
Ancom Exterior & Interior
(204) 223-9798
Winnipeg, MB

Data Provided by:
All Canadian Renovations Ltd.
(204) 779-6900
Winnipeg, MB

Data Provided by:
All Canadian Renovations Ltd.
(204) 779-6900
Winnipeg, MB

Data Provided by:
Ancom Exterior & Interior
(204) 223-9798
Winnipeg, MB

Data Provided by:
Heritage Drywall
(204) 725-1185
3 Imperial Cres
Brandon, MB
 
Baker Drywall
(204) 728-9198
2118 Queens Avenue
Brandon, MB
 
Ray's Drywall & Construction
(204) 728-1627
3 23rd Street North
Brandon, MB
 
Data Provided by:

Soaping Masonry

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: January 1, 2002

What are soaps in masonry walls and when are they used? The term "soap" is often used to describe masonry units cut to reduce their depth. The Brick Industry Association (BIA) defines soaps as "A masonry unit of normal face dimensions having a nominal 2-inch. thickness." In actual construction, I have seen soaps cut down to a depth of 1 inch.

They are often used where a reduction in depth is needed to conceal obstructions within the masonry wall. Soaps are used in front of bolts, flanges of embedded lintel beams, or to cover the projecting edge of the slab.

Soaps can present problems in wall systems. They are very difficult to anchor because of their reduced depth. The problem is particularly prevalent if there are multiple adjacent courses of soaps in a wall. Also, because soap units are positioned at the exterior face of the wall, compressive loads within the exterior wythe must be transferred through these soaps. Masonry loads within the soaps do not coincide with the loads in the center of the wall. This situation can result in buckling. Soaps within masonry veneers should be avoided.

I have also heard the term soap used to describe units cut to reduce their height. The use of units with reduced height should not impact the structural stability of the wall or negatively impact durability.

Click here to read full article from Masonry Construction